Smoke & Ionisation Detector Alarms

Model FID-H

This model is a 9V battery operated Ionization Smoke Detector for Domestic Use with internal sounder. It uses a 9V alkaline battery and has a battery missing indicator, low battery indicator  

A Red LED flashes at 45-second intervals to indicate the detector is operational.

The model FID-H has been designed, tested and complies to AS 3786 and listed in the ActivFire equipment, listing number afp-937.

Model FID-N

This model is an Ionization Smoke Detector. 12-24VDC operation for connection to a security panel with a NC/NO relay output. Alarm signal via an internal sounder and fast flashing red LED.

A Red LED flashes at 45 second intervals to indicate the detector is operational.

The model FID-N has been designed, tested and complies to AS 3786 and listed in the ActivFire equipment, listing Number afp-939.

Model FID-L

This model is an Ionization Smoke Detector. 12-24VDC operation for connection to a security panel with a NO/NC relay output. Alarm signals via an Internal Sounder and Latching Red LED.

A Red LED flashes at 45 second intervals to indicate the detector is operational.

The model FID-L has been designed, tested and complies to AS 3786 and listed in the ActivFire equipment, listing Number afp-922.

Model FID-P

This model is an Ionization Smoke Detector. Designed for connection to mains power via a step down transformer Firetronics PP 139 with provision for a 9V alkaline battery back up. Alarm signals via internal sounder and a Flashing red LED.

A Red LED flashes at 45-second intervals to indicate the detector is operational.

The model FID-P has been designed and tested and complies to AS 3786 and listed in the ActivFire equipment, listing number afp-940.

Model FID-NP

This model is an Ionization Smoke Detector. 12-24VDC operation for connection to the Firetronics Micro 2001 Fire Indicating / Evac panel. Alarm signals via internal sounder and through the Micro 2001 panel sounder and fast flashing red LED.

A Red Led flashes at 45 second intervals to indicate detector is operational.
This model falls under the heading of the FID-N listing and compliance.

Model FID-M

This model is an Ionization Smoke Detector 240VAC with a rechargeable battery back up.

A Red LED flashes at 45 second intervals to indicate detector is operational.
A Green LED on the base indicates the mains power is on. Alarm signal via internal sounder and a fast flashing LED.

These detectors are interlinkable, up to 12 Firetronics Smoke detectors. This model complies to AS 3786 AS 3100-1994. Certified by the department of Energy as meeting electrical safety requirements Approval number CS 6747N.

Model FID-MRLI

This is an Ionization Smoke Detector 240VAC with rechargeable battery back up and free contact relay output.

A Red LED flashes at 45 second intervals to indicate detector is operational.
A Green LED on the base indicates the mains power is on. Alarm signal via internal sounder and a fast flashing LED.

This model is Interlinkable to the same models detectors.

Model FID-M HUSH

This model is an Ionization Smoke Detector 240VAC with a rechargeable battery back up.

A Red LED flashes at 45 second intervals to indicate detector is operational.
A Green LED on the base indicates the mains power is on. Alarm signal via internal sounder and a fast flashing LED , with wall mounted Hush Button for the disabled / elderly.

This detector is Interlinkable to other FID-M detectors.

Model FID-N 48V

This model is an Ionization Smoke Detector Alarm. 48VDC operation with a NC/NO relay output with a special design circuit board for 48V operation. Alarm signal via an internal sounder and fast flashing red LED.

A Red LED flashes at 45 second intervals to indicate detector is operational.

Model FID-HSC

This model is an Ionization Smoke Detector 9V battery operation. This model has been especially designed for connection to Smart Caller Nurse Call system, via an extra transmitter board that gets fitted into the base of the smoke detector alarm.

A Red LED flashes at 45 second intervals to indicate detector is operational.

Alarm signal via internal sounder and a fast flashing LED,and Smart Caller System.

Model FID-HRLY

This model is a 9V battery operated Ionization Smoke Detector Alarm with a NC/NO relay output. Alarm signal via an internal sounder and fast flashing red LED. It uses a 9V alkaline battery and has a battery missing/low battery indicator.

A Red LED flashes at 45 second intervals to indicate detector is operational.